|◀ 649 - 660 of 747 ▶|
View:
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

Model VR1T converts a 24VAC or 24VDC input into a regulated 12VDC @ 1A output.

Features

  • Quick release terminals(wire gauge 14-20AWG).
  • Lightweight molded compact insulated housing.
  • Compact design allows for integration in a wide range of camera housings.

Item#:
VR1T
You must be logged in to order this item. Log in here

Trove3 enclosure with THW3 Altronix/Honeywell backplane:

  • Backplane accommodates a combination of Honeywell ProWatch/WinPak boards with or without Altronix accessories: Honeywell - PRO32IC, PRO32R2, PRO32IN, PRO32OUT, PW51KEN, PW6K1IC, PW6K1IN, PW6K1OUT, PW6K1R2, PRO32E1PS, PW6K2E2PS, PRO22MX8, Altronix Power Supplies, Altronix Sub-Assemblies
  • Includes Altronix Trove3 Enclosure and one (1) removable THW3 backplane
Trove3 Enclosure:
  • 16 AWG powder coated steel enclosure with a single 2" center knockout on the top of the enclosure plus (16) 2-Stage knockouts for 0.75" or 1" conduit.
  • Includes: One (1) cam lock, one (2) tamper switch and mounting hardware.

Item#:
TROVE3HW3
You must be logged in to order this item. Log in here

Trove3 enclosure with TCV3 Altronix/CDVI backplane:

  • Backplane accommodates a combination of CDVI Atrium controllers with or without Altronix accessories: CDVI Atrium A22, Altronix Power Supplies, Altronix Sub-Assemblies
  • Includes Altronix Trove3 Enclosure and one (1) removable TCV3 backplane
Trove3 Enclosure:
  • 16 AWG powder coated steel enclosure with a single 2" center knockout on the top of the enclosure plus (16) 2-Stage knockouts for 0.75" or 1" conduit.
  • Includes: One (1) cam lock, one (2) tamper switch and mounting hardware.

Item#:
TROVE3CV3
You must be logged in to order this item. Log in here
Altronix T1RM3F4 rack kit is pre-assembled and consists of Trove1M1R enclosure/backplane with factory installed Altronix power supply/charger and sub-assemblies. This kit also accommodates various combinations of Mercury boards for up to four (4) doors in a single enclosure.
Power Supply (eFlow6NB):
Input
  • Voltage: 120VAC, 60Hz, 3.5A max.
  • Fusing: 5A / 250V.
Output
  • Voltage: Factory set at 24VDC.
  • Current: 6A continuous.
  • Maximum Supply Current for Main and Aux. Outputs on eFlow6NB Power Supply board, PDS8 Power Distribution Module’s and ACM4 Access Power Controller’s outputs is 5.6A.
  • Auxiliary: Class 2 power-limited @ 1A (unswitched).
  • Other: Overvoltage protection. Filtered and regulated.
Battery Backup
  • Built-in charger for sealed lead acid or gel type batteries (if batteries are required, install separate battery enclosure RE2).
  • Automatic switch over to stand-by battery when AC fails.
  • Zero voltage drop when unit switches over to battery backup (AC failure condition).
Fire Alarm Disconnect
  • Supervised: Latching or non latching.
  • EOL: 10K Resistor.
Supervision
  • AC Failure: Form “C” contacts.
  • Battery: Form “C” contacts.
  • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
Indicators LED
  • Input: 120VAC is present.
  • DC Output: Powered.
  • Battery: Discharged or not connected.
Access Power Controller (ACM4):
Input
  • Voltage: 24VDC from eFlow6NB.
  • Fusing: 10A / 250V.
Output
  • Voltage: 24VDC.
  • Four (4) independently controlled 2.5A outputs:
  • a) Four (4) Fail-Safe and/or Fail-Secure power outputs.
  • b) Four (4) dry form “C” 5A rated relay outputs.
  • c) Any combination of the above.
  • Four (4) auxiliary power outputs (unswitched).
  • Fuses Rating: 3A / 32VDC.
Indicators (LED's)
  • Red LEDs: Outputs are triggered (relays energized).
  • Green LED: FACP disconnect is triggered.
Power Distribution Module (PDS8):
Input
  • Voltage: 24VDC from eFlow6NB and 12VDC from VR6.
  • Fusing: 10A / 250V.
Output
  • Voltage: 12 or 24VDC individually selectable.
  • Fuses Rating: 3A / 32VDC.
Indicators (LED)
  • DC Output: Eight (8) individual output LEDs.
Item#:
T1RM3F4
You must be logged in to order this item. Log in here

Model VR1 converts a 24VAC or 24VDC input into a regulated 12VDC @ 1A output.

Features

  • Modular connector/cable assembly facilitates ease of wiring.
  • Compact design allows for integration in a wide range of camera housings.

Item#:
VR1
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

  • 16 AWG backplane.
  • Includes mounting hardware.
  • Accommodates the following Software House iStar Ultra series access controllers with or without Altronix power/accessories: iStar Ultra GCM and iStar Ultra ACM boards or iSTAR Pro GCM and iSTAR ACM SE/PRO ACM boards, as well as I8, R8, and I8-CSI boards, Altronix Power Supplies, Altronix Sub-Assemblies
  • Simplifies board layout and wire management
  • 16 AWG galvanized steel

Item#:
TSH3
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here