AL400ULXR is a power supply/charger that converts a 115VAC/60Hz input into a single 12VDC or 24VDC Class 2 Rated power-limited output.

Input

  • Input 115VAC, 60Hz, 3.5A.
  • Input fuse rated @ 3.5A/250V.
Output
  • 12VDC or 24VDC selectable output.
  • Burglar Alarm Applications(UL 603):
  • 12VDC = 11.5VDC-13VDC.
  • 24VDC = 23VDC-26VDC.
  • 12VDC @ 4A or 24VDC @ 3A supply current.
  • Class 2 Rated power limited output.
  • Filtered and electronically regulated output.
  • Short circuit and thermal overload protection.

Item#:
AL400ULXR
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

Altronix AL175ULX is a Two (2) Output Switching Power Supply/Charger that converts a 115VAC 60Hz input, into two (2) individually PTC protected 12VDC or 24VDC outputs.

Input

  • Input 115VAC, 60Hz, 0.6A.
  • Access control trigger input.
Output
  • 12VDC or 24VDC selectable outputs.
  • 1.75A supply current.
  • Two (2) Class 2 Rated power limited outputs.
  • Fail-Safe/Fail-Secure lock output (switched).
  • Auxiliary power output (unswitched).
  • PTC protected outputs, rated @ 2.5A.
  • Filtered and electronically regulated output.
  • Short circuit and thermal overload protection.

Item#:
AL175ULX
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

AL600ULX is a power supply/charger which converts a 115VAC/60Hz input into a single 12VDC or 24VDC non power-limited output.

Input

  • Input 115VAC, 60Hz, 3.5A.
Output
  • 12VDC or 24VDC selectable output.
  • 6A continuous supply current.
  • Filtered and electronically regulated output.
  • Short circuit and thermal overload protection.

Item#:
AL600ULX
You must be logged in to order this item. Log in here

Altronix AL1024ULACM converts a 115VAC 60Hz input into eight (8) independently controlled 24VDC Fail-Safe and/or Fail-Secure outputs with a total of 10A continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.

Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
    Fire Alarm disconnect input options:
    • a) Normally open (NO) or normally closed (NC) dry contact input.
    • b) Polarity reversal input from FACP signaling circuit.
  • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC not evaluated by UL).
  • Short circuit and thermal overload protection.

Item#:
AL1024ULACM
You must be logged in to order this item. Log in here

Altronix AL600ULACM converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC Fail-Safe and/or Fail-Secure outputs with a total of 6A continuous supply current. These power outputs can be converted to dry form "C" contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.

Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
    Fire Alarm disconnect input options:
    • a) Normally open (NO) or normally closed (NC) dry contact input.
    • b) Polarity reversal input from FACP signaling circuit.
    • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC).
    • Short circuit and thermal overload protection.
    • AC fail supervision (form "C" contact).