|◀ 25 - 36 of 119 ▶|
View:

  • 6 Programmable Initiating Device Circuits
  • System is expandable to 192 input circuits using the IDC-6 expansion module
  • 5.0 Amp Power Supply
  • 4 Notification Circuit rated at 3.0 Amps
  • Strobe Synchronization for Gentex, AMSECO, System Sensor and Cooper/Wheelock
  • One programmable auxiliary output rated at 1.0 A
  • 4 x 20 LCD display with system LEDs for clear system status
  • P-Link RS-485 bus supports 31 system accessories
  • Built-in Ethernet Connection with listed IP Communicator
  • Ability to E-mail system status, reports and system configuration
  • Service Reminder E-mails

Item#:
3992360
You must be logged in to order this item. Log in here

  • 50 addresses available on this analog addressable system
  • Additional system capacity achieved via multi-point SLC modules
  • 99 software zones
  • NFPA 72 Compliant Smoke Sensitivity Test Built-In
  • System Operates as Class A or Class B for SLC, P-Link and NACs
  • 5 Amp Power Supply, Expandable to 310 amps
  • 2 NACS, Regulated, Rated at 3 Amps each, expandable to 188
  • 2 Input/Output (I/O) Circuits for system flexibility rated at 1 Amp each
  • Strobe Synchronization and System Wide Sync for Gentex, AMSECO, Cooper Wheelock and System Sensor strobes
  • Dedicated Alarm, Supervisory and Trouble Relays
  • 4,000 Event History Buffer
  • Optional two line DACT with UD-1000 that can report General, Zone or Point Information
  • Built in IP Communicator
  • Ethernet Port for Programming and Network Connectivity
  • E-Mail System Status, Reports and Event Information
  • Product includes 5 year warranty

Item#:
3992752
You must be logged in to order this item. Log in here
Maximum 198 point single loop addressable fire alarm control panel. Includes connected panel options, enhanced communications, wireless detection and other advanced features. (Replaces the 5808)
  • Connect up to 17 panels with convenient single point visability. Copper wire or fiber optic cable panel connectivity can be used within the same linked system. Compatible FACPs can be linked within one system
  • Built-in dual path IP and POTs communication for reliable dual path backup
  • Built-in USB interface for convenient and speedy programming
  • SWIFT® capable for wireless detection -- perfect for hard-to-wire installs
  • Field-upgradeable firmware saves time and money - no need to return panels for updates
  • Supports up to 12 remote annunciators for convenient and efficient system status reporting
  • Large easy-use keypad and 4 x 20 - 80 character display
  • Includes access to Jumpstart™, HFSS programming software and the SKST selection tool
  • NAC Circuits: 4; 6 amps power supply
  • Supports Class B (Style 4) and Class A (Style 6) configuration for SLC, SBUS, and Flexput circuit
Item#:
006808
You must be logged in to order this item. Log in here

The SK-ZONE-6 is addressable six circuit zone module that allows an IntelliKnight fire alarm controls to interface and monitor two-wire conventional smoke detectors.

Features

  • Converts a conventional two-wire loop to an address on the SLC loop
  • Six zone inputs
  • Rotary address switches for fast installation
  • Support for Class B and Class A wiring
  • Individual LED for each zone circuit
  • Up to two unused circuits can be disabled
  • UL listed

Item#:
SK-ZONE-6
You must be logged in to order this item. Log in here

The SK-RELAY is an addressable relay module that allows an IntelliKnight fire alarm control to switch discrete contacts by code command. The module contains two isolated sets of Form C contacts.

Features

  • Two sets of Form C contacts
  • Rotary address switches for fast installation
  • Relay programming is completely flexible  can be mapped to zone conditions
  • Bright white cover plate
  • SEMS screws for easy wiring
  • UL listed

Item#:
SK-RELAY
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
Maximum 1,110 point addressable fire alarm control panel. Includes connected panel options, enhanced communications, wireless detection and other advanced features. (Replaces the 5820XL).
  • Connect up to 17 panels with convenient single point communications. Copper wire or fiber optic cable panel connectivity can be used within the same linked system
  • Multiple Signal Line Circuits (SLCs) can be used within one system limited only by maximum points available
  • Built-in dual path IP and POTs communication for reliable dual path backup
  • Built-in USB interface for convenient and speedy programming
  • SWIFT® capable for wireless detection
  • Convenient field-upgradeable firmware
  • Supports up to 16 remote annunciators
  • Programmable date setting for automatic and convenient Daylight Saving Time changes
  • 4 x 20 annunciator with 80 character display and large easy-use keypad
  • Includes access to Jumpstart™, HFSS programming software and the SKST selection tool
  • NAC Circuits: 6; 6 amps power supply
  • Supports Class B (Style 4) and Class A (Style 6) configuration for SLC, SBUS, and Flexput circuit
Item#:
006820
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

Fire Alarm Control Panel, 4-Zone, Class B/A (Use CAC-4 for ClassA), 24VDC, 1 Classs B/A (Use CAC-4 for Class A) NAC

MS-4 is a four zone conventional fire alarm control panel compatible with the new I3 smoke detectors from System Sensor, and provides such advanced features as drift compensation, maintenance alert, and freeze warning. Automatic synchronization of audio/visual devices is provided, using manufacturer protocol for System Sensor, Wheelock and Gentex appliances. The NAC protocol includes the ability to silence audible devices while strobes continue to flash, using only a single pair of wires.

Features

  • Four initiating zones compatible with 2- and 4-wire smoke detectors, one zone programmable for combo, supervisory and waterflow
  • Two NACs with built-in horn/strobe synchronization for System Sensor, Wheelock or Gentex with selectable silence Optional module to convert all four initiating zones and two NACs to Class A
  • Compatible with System Sensors smoke detectors, providing EZ Walk Test and a Remote Maintenance Signal (panel is offered as i3 Ready, no additional modules needed)
  • 3.0 amps total usable current and expandable to 6.0 amps total with optional second transformer
  • Options include a plug-in 4XTMF transmitter module, a 4XLMF module to support LED annunciators and a plug-in 4XZMF zone relay module

`
Item#:
MS-4
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
|◀ 25 - 36 of 119 ▶|
View: