Altronix T2SK7F8 is pre-assembled and consists of Trove2 enclosure with factory installed Altronix power supply/chargers and sub-assemblies. These kits also accommodates various combinations of Software House boards for up to eight (8) doors in a single enclosure.

  • Input: 120VAC 60Hz/4.5A.
  • Output:
    • 24VDC up to 9.2A max current.
    • Eight (8) Fail-Safe/Fail-Secure or Dry Form "C" Outputs
  • Fully assembled kit includes:
    • Trove2 enclosure with TSH2 backplane
    • One (1) eFlow104NB - Power Supply/Charger
    • One (1) ACM8 - Fused Access Power Controller
    • One (1) VR6 - Voltage Regulator
    • One (1) PDS8 - Dual Input Power Distribution Module
    • One (1) Rocker Switch Bracket with One (1) Rocker Switch
  • Back-up Battery (not included):
    • Capacity: 12AH / 12VDC (Up to 4 within enclosure); 40 AH / 65 AH (requires separate enclosure).
    • Type - Sealed lead acid or gel type.
    • Fuse Rating: 15A/32V.
    • Failover - Upon AC loss, instantaneous.
  • Supervision:
    • AC Failure - Form "C" contacts.
    • Battery - Form "C" contacts.
    • Low DC Power Shutdown - Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
  • LED Indicators:
    • Input - 120VAC is present.
    • DC Output - Powered.
    • Battery - Discharged or not connected.

Item#:
T2SK7F8
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

Altronix T2MK3F4 is are pre-assembled and consists of Trove2M2 enclosure with factory installed Altronix power supply/charger(s) and sub-assemblies. These kits also accommodates various combinations of Mercury boards for up to four (4) doors in a single enclosure.

  • Input: 120VAC 60Hz/3.5A.
  • Output:
    • 24VDC up to 5.8A max current.
    • Four (4) Fail-Safe/Fail-Secure or Dry Form "C" Outputs
  • Fully assembled kit includes:
    • Trove2 enclosure with TM2 backplane
    • One (1) eFlow6NB - Power Supply/Charger
    • One (1) ACM4 - Fused Access Power Controller
    • One (1) VR6 - Voltage Regulator
    • One (1) PDS8 - Dual Input Power Distribution Module
  • Back-up Battery (not included):
    • Capacity: 12AH / 12VDC (Up to 4 within enclosure); 40 AH / 65 AH (requires separate enclosure).
    • Type - Sealed lead acid or gel type.
    • Fuse Rating: 10A/32V
    • Failover - Upon AC loss, instantaneous.
  • Supervision:
    • AC Failure - Form "C" contacts.
    • Battery - Form "C" contacts.
    • Low DC Power Shutdown - Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
  • LED Indicators:
    • Input - 120VAC is present.
    • DC Output - Powered.
    • Battery - Discharged or not connected.

Item#:
T2MK3F4
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
Altronix T1RAL3F8 rack kit is pre-assembled and consists of Trove1AL1R enclosure/backplane with factory installed Altronix power supply/ charger(s) and sub-assemblies.
Power Supply (eFlow6NB):
Input
  • Voltage: 120VAC, 60Hz, 3.5A max.
  • Fusing: 5A / 250V.
Output
  • Voltage: Factory set at 24VDC.
  • Current: 6A continuous.
  • Maximum Supply Current for Main and Aux. Outputs on eFlow6NB Power Supply board, ACMS8 Access Power Controller’s and PDS8 Power Distribution Module’s outputs is 5.6A.
  • Auxiliary: Class 2 power-limited @ 1A (unswitched).
  • Other: Overvoltage protection. Filtered and regulated.
Battery Backup
  • Built-in charger for sealed lead acid or gel type batteries (if batteries are required, install separate battery enclosure RE2).
  • Automatic switch over to stand-by battery when AC fails.
  • Zero voltage drop when unit switches over to battery backup (AC failure condition).
Fire Alarm Disconnect
  • Supervised: Latching or non latching.
  • EOL: 10K Resistor.
Supervision
  • AC Failure: Form “C” contacts.
  • Battery: Form “C” contacts.
  • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. Prevents deep battery discharge.
Indicators LED
  • Input: 120VAC is present.
  • DC Output: Powered.
  • Battery: Discharged or not connected.
Power Distribution Module (PDS8):
Input
  • Voltage: 24VDC from eFlow6NB and 12VDC from VR6.
  • Fusing: 10A / 250V.
Output
  • Voltage: 12 or 24VDC individually selectable.
  • Fuses Rating: 3A / 32VDC.
Indicators (LED's)
  • DC Output: Eight (8) individual output LEDs.
Access Power Controller (ACMS8):
Input
  • Voltage: 24VDC from eFlow6NB and 12VDC from VR6.
  • Fusing: 15A / 32V.
Output
  • Voltage: 12 or 24VDC individually selectable.
  • Eight (8) selectable 12VDC - 24VDC independently controlled outputs or eight (8) indepently controlled Form “C” relay outputs:
  • a) Fail-Safe and/or Fail-Secure power outputs.
  • b) Form “C” Relays. 28VAC or VDC @ 2.5A Rated.
  • c) Auxiliary power outputs (unswitched).
  • d) Any combination of the above.
  • Any of the eight (8) fuse protected power outputs are selectable to follow power Input 1 or Input 2.
  • Individual outputs may be set to OFF position for servicing.
  • Fuses Rating: 2.5A / 32VDC.
Indicators (LED)
  • Red LEDs: Outputs are triggered (relays energized).
  • Blue LED: FACP disconnect is triggered.
Individual voltage LEDs
  • Green: 12VDC
  • Red/Green: 24VDC
Item#:
T1RAL3F8
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

Trove3 enclosure with TBL3 backplane:

  • Backplane accommodates any manufacturers boards and equipment
  • Includes Altronix Trove3 Enclosure and one (1) removable TBL3 backplane
Trove3 Enclosure:
  • 16 AWG powder coated steel enclosure with a single 2" center knockout on the top of the enclosure plus (16) 2-Stage knockouts for 0.75" or 1" conduit.
  • Includes: One (1) cam lock, one (2) tamper switch and mounting hardware.

Item#:
TROVE3BL3
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

Altronix T2MK75F16D is pre-assembled and consists of Trove2M2 enclosure with factory installed Altronix power supply/charger(s) and sub-assemblies. This kit also accommodates various combinations of Mercury boards for up to sixteen (16) doors in a single enclosure.

  • Input: 120VAC 60Hz/8A.
  • Output:
    • 12VDC up to 9.3A and 24VDC up to 9.2A max current.
    • Sixteen (16) Fail-Safe/Fail-Secure or Dry Form "C" Outputs
  • Fully assembled kit includes:
    • Trove2 enclosure with TM2 backplane and TMV2 door backplane
    • One (1) eFlow104NB and (1) eFlow102NB - Power Supply/Chargers
    • Two (2) ACM8CB - PTC Access Power Controller
    • One (1) PD8ULCB - Power Distribution Module

Item#:
T2MK75F16D
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

Altronix T2MK77F16Q is pre-assembled and consists of Trove2M2 enclosure with factory installed Altronix power supply/charger(s) and sub-assemblies. This kit also accommodates various combinations of Mercury boards for up to sixteen (16) doors in a single enclosure.

  • Input: 120VAC 60Hz/9A.
  • Output:
    • 24VDC up to 9.2A max current.
    • Sixteen (16) Fail-Safe/Fail-Secure or Dry Form "C" Outputs
  • Fully assembled kit includes:
    • Trove2 enclosure with TM2 backplane and TMV2 door backplane
    • Two (2) eFlow104NB - Power Supply/Charger
    • One (1) LINQ2 - Network Communications Module
    • Two (2) ACM8 - Fused Access Power Controller
    • One (1) VR6 - Voltage Regulator
    • One (1) PDS8 - Dual Input Power Distribution Module
  • Back-up Battery (not included):
    • Capacity: 12AH / 12VDC (Up to 4 within enclosure); 40 AH / 65 AH (requires separate enclosure).
    • Type - Sealed lead acid or gel type.
    • Fuse Rating: 15A/32V
    • Failover - Upon AC loss, instantaneous.
  • Supervision:
    • AC Failure - Form "C" contacts.
    • Battery - Form "C" contacts.
    • Low DC Power Shutdown - Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
  • LED Indicators:
    • Input - 120VAC is present.
    • DC Output - Powered.
    • Battery - Discharged or not connected.

Item#:
T2MK77F16Q