|◀ 385 - 396 of 431 ▶|
View:

SMP3PMCTX supervised power supply/charger will convert a 115VAC/230VAC, 50/60Hz input, into a regulated 12VDC or 24VDC output @ 2.5A continuous supply current.

Specifications:
Input:

  • Input 115VAC, 50/60Hz, 0.65A or 230VAC, 50/60Hz, 0.35A.
Output:
  • 12VDC or 24VDC selectable output.
  • 2.5A supply current.
  • Filtered and electronically regulated outputs.
  • Short circuit and thermal overload protection.
Battery Backup:
  • Built-in charger for sealed lead acid or gel type batteries.
  • Zero voltage drop when switching over to battery backup.
Supervision:
  • AC fail supervision (form C contacts).
  • Low battery supervision (form C contacts).
Visual Indicators:
  • AC input and DC output LED indicators.
Temperature:
  • Operating 0° C to 49° C (32° F to 120° F).
  • Storage - 20° C to 70°C ( - 4° F to 158° F).
  • Relative Humidity 85% +/- 5%.
  • BTU/Hr (approx.):
    • 12VDC: 15 BTU/Hr.
    • 24VDC: 31 BTU/Hr.
  • System AC input VA requirement:
    • 115VAC: 74.75VA.
    • 230VAC: 80.5VA.

Item#:
SMP3PMCTX
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

OLS180 power supply/charger converts a 115VAC, 50/60Hz input into a 12VDC or 24VDC output @ 6A continuous supply current (see specifications). This unit has a wide range of applications for access control and security system accessories that require additional power.

Features:

  • Power ON/OFF switch.
  • Includes battery leads.
Specifications:
  • Input:
    • 115VAC, 50/60Hz, 1.9A.
    Output:
    • 12VDC or 24VDC selectable output.
    • 6A continuous supply current.
    • Filtered and electronically regulated output.
    • Short circuit and thermal overload protection.
    Battery Backup:
    • Built-in charger for sealed lead acid or gel type batteries.
    • Automatic switch over to stand-by battery when AC fails.
    Supervision:
    • AC fail supervision (form C contacts).
    • Low battery supervision (form C contacts).
    Visual Indicators:
    • AC input and DC output LED indicators.
    Electrical:
    • Temperature:
      • Operating: 0° C to 49° C (32° F to 120° F).
      • Storage: - 20° C to 70° C ( - 4° F to 158° F).
    • Relative Humidity 85% +/- 5%.
      • BTU/Hr (approx.):
        • 12VDC: 37 BTU/Hr.
        • 24VDC: 74 BTU/Hr.
    • System AC input VA requirement: 218.5VA.

  • Item#:
    OLS180
    You must be logged in to order this item. Log in here
    You must be logged in to order this item. Log in here

    The PS3002 is a 12-volt, 1.9-ampere continuous regulated power supply. Designed to support numerous control panels, the module increases the panels available standby current and provides an ac-only mode of operation as required by UL and NFPA for residential fire applications. A 50VA, 16.5-volt transformer and all required mounting hardware are supplied.

    The PS3002 is UL listed for Central Station, Police Station Connect, Household Fire and Household Burglar Alarm System Units. (For UL Certified installations, the PS3002 must be wired as part of a supervised system.

    In the ac-only mode, the PS3002 can supply auxiliary and/or siren current up to a maximum total of 1.9 ampereswhere the auxiliary current from the PS3002 does not exceed 1.4 amperes.

    Item#:
    PS3002
    You must be logged in to order this item. Log in here

    Features:

    • Connect up to 16 modules
    • 4 programmable form C relays at 2 Amps @ 30 VDC
    • Fully supervised for AC failure, low battery and AUX failure

    Item#:
    PC4204CX
    You must be logged in to order this item. Log in here
    You must be logged in to order this item. Log in here
    You must be logged in to order this item. Log in here
    You must be logged in to order this item. Log in here
    You must be logged in to order this item. Log in here
    |◀ 385 - 396 of 431 ▶|
    View:
    (Denotes required field.)