- Connect up to 17 panels with convenient single point communications. Copper wire or fiber optic cable panel connectivity can be used within the same linked system
- Multiple Signal Line Circuits (SLCs) can be used within one system limited only by maximum points available
- Built-in dual path IP and POTs communication for reliable dual path backup
- Built-in USB interface for convenient and speedy programming
- SWIFT® capable for wireless detection
- Convenient field-upgradeable firmware
- Supports up to 16 remote annunciators
- Programmable date setting for automatic and convenient Daylight Saving Time changes
- 4 x 20 annunciator with 80 character display and large easy-use keypad
- Includes access to Jumpstart™, HFSS programming software and the SKST selection tool
- NAC Circuits: 6; 6 amps power supply
- Supports Class B (Style 4) and Class A (Style 6) configuration for SLC, SBUS, and Flexput circuit
- New modern profile for improved aesthetics
- Stable communication technique with noise immunity
- Low standby current
- Two-wire SLC connection
- Optional remote, single- gang LED accessory
- Dual LED design provides 360° viewing angle
- Remote test feature from the panel
- Built-in functional test switch activated by external magnet
- Built-in tamperresistant feature
- Sealed against back pressure
- Expanded color options
- SEMS screws for wiring of the separate base
- Optional relay, isolator, and sounder bases
- Plugs into separate base for ease of installation and maintenance
Fire-Lite's MMF-300-10(A) ten-input monitor module provides an interface between the MS-9050UD, MS-9200UDLS, and MS-9600(UD)LS and normally open contact devices such as pull stations, security contacts or flow switches. Provisions are included for disabling a maximum of two unused addresses.
Features
Addressable Fire Alarm Control with Upload/Download, 636 Points on Two Signaling Line Circuit's (SLC's), with built in Dialer, (2nd SLC Optional, 24VDC
MS-9600LS is a 318-point addressable fire alarm control panel with optional Digital Alarm Communicator/Transmitter (DACT-UD2) and expandable to 636 addressable points with an optional second Signaling Line Circuit (SLC-2LS).
- Up to 159 detectors and 159 control/monitor modules (total of 318 devices) per SLC (636 with SLC-2LS option card)
- Uses PS-Tools programming utility
- LiteSpeed protocol for SLC communication polls 10 devices at a time and operates on standard, unshielded wire
- Auto programmable function reduces installation time
- Advanced Fire Technology includes sensitivity testing and automatic drift compensation
- 7 amps of power distributed across 4 NAC circuits with onboard Sync Select for System Sensor, Gentex , or Wheelock devices