The Endurance Series ES-50X is a 50-point addressable fire alarm control panel that offers built-in dual path communications, programmable buttons and support for combined fire and CO addressable detection.
  • Upload/Download panel programming database and flash firmware with USB thumb drive
  • Addressable multi-criteria detector (smoke, heat, CO) with programmable response
  • Addressable Sounder Bases
  • Four programmable function keys
  • Built in Class-A capability for all 2 NACs; no optional card required
  • Trouble indication for SLC devices not programmed
  • Automatic discovery of "relay" versus "NAC" type control modules during auto-programming of SLC loop
  • Integrated SWIFT display driver and annunciator built-in to panel
Item#:
ES-50X
You must be logged in to order this item. Log in here

MS-5UD-3 is a five zone conventional fire control panel has features normally found in more expensive addressable systems. The MS-5UD-3 is fully programmable via built-in keypad and 80 character LCD display, so you do not need an external programmer. The five zones panel has a built-in Digital Alarm Communicator Transmitter (DACT) and availability to add optional equipment: Remote annunciator, Relay module, LED Driver module, Transmitter module and Printer interface module.

Features

  • Five-zone Style B (Class B) or Five-zone Style D (Class A) with optional module
  • Four NAC Circuits Style Y (Class B) or Four NAC Circuits Style Z (Class A) with optional modules
  • Built-in NAC synchronization for System Sensor, Wheelock, Gentex, Faraday and Amseco devices
  • Integral 80 character LCD display with backlighting and keypad
  • Annunciator bus supports up to 8 devices, including ANN-80 LCD Remote Annunciator, ANN-S/PG remote serial or parallel printer gateway, ANN-RLY, 10 form C relay board, ANN-LED Zone annunciator and ANN-I/O LED driver board for graphic annunciators
  • Built-in two-line digital communicator for off premises monitoring
  • Three Form-C programmable relays
  • 3.0 amps total usable current

Item#:
MS-5UD-3
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

The EVS-50W is an intelligent 50 watt amplifier for use with version 14.0 or newer 5820XL-EVS. The EVS-50W is used to amplify audio messaging throughout an area or facility. The EVS-50W is capable of producing 50 watts of audio power over 4, expandable to 8, fully programmable speaker circuits.

Features

  • 50 watts of audio power
  • Comes with 4 fully programmable Class A or Class B speaker circuits
  • 25 or 70.7 Vrms operation
  • Expansion up to 8 speaker circuits with the EVS-CE4
  • Six wire connection to the 5820XL-EVS system: two wires for the Voice Bus (VBUS) and four wires for the SBUS connections
  • Can be mounted up to 6000 feet away from the 5820XL-EVS control panel
  • 120 VAC or 240 VAC operation
  • UL 864 and UL 2572

Item#:
EVS-50W
You must be logged in to order this item. Log in here
Item#:
CS05-482-114
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80 is red; for white, order ANN-80-W.
The ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes control switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.)
Up to eight ANN-80s may be connected to the ANN-BUS of each FACP. No programming is required, which saves time during system commissioning.

Features

  • Listed to UL Standard 864, 9th Edition.
  • Backlit 80-character LCD display (20 characters x 4 lines).
  • Mimics all display information from the host panel.
  • Control switches for System Acknowledge, Signal Silence, Drill, and Reset.
  • Control switches can be independently enabled or disabled at the FACP.
  • Keyswitch enables/disables control switches and mechanically locks annunciator enclosure
  • Keyswitch can be enabled or disabled at the FACP.
  • Enclosure supervised for tamper.
  • System status LEDs for AC Power, Alarm, Trouble, Supervisory, and Alarm Silence.
  • Local sounder can be enabled or disabled at the FACP.
  • ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming.
  • Displays device type identifiers, individual point alarm, trouble, supervisory, zone, and custom alpha labels.
  • Time-and date display field.
  • Surface mount directly to wall or to single, double, or 4in. square electrical box.
  • Semi-flush mount to single, double, or 4" square electrical box. Use ANN-SB80KIT for angled view mounting.
  • Can be remotely located up to 6,000 feet (1,800 m) from the panel.
  • Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs.
  • May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC).
  • Up to eight ANN-80s can be connected on the ANN-BUS

Item#:
ANN-80
You must be logged in to order this item. Log in here