Home  >  FIRE  > (x)
|◀ 193 - 204 of 8053 ▶|
View:
You must be logged in to order this item. Log in here

Fire-Lite's MMF-300-10(A) ten-input monitor module provides an interface between the MS-9050UD, MS-9200UDLS, and MS-9600(UD)LS and normally open contact devices such as pull stations, security contacts or flow switches. Provisions are included for disabling a maximum of two unused addresses.

Features

  • Ten addressable Class B or five addressable Class A initiating device circuits.
  • Removable plug-in terminal blocks.
  • Status indicators for each point.
  • Unused addresses may be disabled.
  • Rotary address switches.
  • Class A or Class B operation.
  • Flexible mounting options.

Item#:
MMF-300-10
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

MDF-300 Dual Monitor Module The MDF-300(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent twowire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panelcontrolled LED.

Item#:
MDF-300
You must be logged in to order this item. Log in here

Alarm Current: 75mA (max.); 54mA (12V In), 32mA (24V In)
Dimensions: Diameter: 6.4 in. ; Width: 6.04 in. ; Depth: 1.00 in
Mounting: 4-11/16 in. square back box or inside a metal enclosure
Operating Humidity Range: 5-95% RH
Operating Temperature Range: 0 – 50° C (32 — 122° F)
Operating Voltage: Nominal: 12/24 VDC; Minimum: 10 VDC; Maximum: 35 VDC (power limited)
Standby Current: 52mA (max.); 36mA (12V In); 20mA (24V In)
Weight: 9.6 oz. (272 g)
Wiring Gauge: 14-22 AWG

Item#:
COSMOD4W
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80 is red; for white, order ANN-80-W.
The ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes control switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.)
Up to eight ANN-80s may be connected to the ANN-BUS of each FACP. No programming is required, which saves time during system commissioning.

Features

  • Listed to UL Standard 864, 9th Edition.
  • Backlit 80-character LCD display (20 characters x 4 lines).
  • Mimics all display information from the host panel.
  • Control switches for System Acknowledge, Signal Silence, Drill, and Reset.
  • Control switches can be independently enabled or disabled at the FACP.
  • Keyswitch enables/disables control switches and mechanically locks annunciator enclosure
  • Keyswitch can be enabled or disabled at the FACP.
  • Enclosure supervised for tamper.
  • System status LEDs for AC Power, Alarm, Trouble, Supervisory, and Alarm Silence.
  • Local sounder can be enabled or disabled at the FACP.
  • ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming.
  • Displays device type identifiers, individual point alarm, trouble, supervisory, zone, and custom alpha labels.
  • Time-and date display field.
  • Surface mount directly to wall or to single, double, or 4in. square electrical box.
  • Semi-flush mount to single, double, or 4" square electrical box. Use ANN-SB80KIT for angled view mounting.
  • Can be remotely located up to 6,000 feet (1,800 m) from the panel.
  • Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs.
  • May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC).
  • Up to eight ANN-80s can be connected on the ANN-BUS

Item#:
ANN-80
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
|◀ 193 - 204 of 8053 ▶|
View:
(Denotes required field.)