- Input for a 26 bit Wiegand Reader, such as ELK-106055
- Input for a Dallas "One-Wire" iButton Reader, such as ELK-MA110
- Heavy Duty Form "C" Relay Contacts for Switching Door Strike Power
- Low Current (50mA) Switched Negative (pull to ground) Output for "Door Held Open" Alarm
- Low Current (10mA) Switched Negative (pull to ground) Output for "System Ready To Arm" indication
- Low Current (10mA) Switched Negative (pull to ground) Output for "System Armed" indication
- Supervised Input for RTE (Request To Exit) Button/Device
- Supervised Input for Door Status Sensor
- Installs in place of an M1 Keypad and operates from the RS-485 4-Wire Keypad Data Bus
- Four selectable Time settings for "Request to Exit" and "Door Held Open"
- Hardware Watchdog Circuit
Item#:
M1KAM
You must be logged in to order this item.
Log in here
Item#:
PROFILE CRS8 THREE
You must be logged in to order this item.
Log in here
Item#:
PROFILE CRS6 TWO
You must be logged in to order this item.
Log in here
Item#:
RP2000LCD
You must be logged in to order this item.
Log in here
Item#:
PROFILE CRS8 ONE
You must be logged in to order this item.
Log in here
Item#:
PROTEGE 6.5" CEILING
You must be logged in to order this item.
Log in here
Item#:
SIGNATURE C895S
You must be logged in to order this item.
Log in here
Item#:
SA-026Q
You must be logged in to order this item.
Log in here
You must be logged in to order this item.
Log in here
An "active" RS-485 data bus hub designed for jobs where an M1Gold or M1EZ8 Control is retrofitting an older panel that has multiple homerun 4 conductor keypad/data wires. It splits the main 485 data bus into 4 managed 485 branches. Each branch can have 2 parallel home run cables for a total of 8 home runs. The end of each cable is EOL terminated to insure proper operation and supervision.
Includes:
- ELK-M1DBHR Data Bus Hub
- ELK-SWG Circuit Board Mounting Glides
- Instructions
- Splits The Controls' RS-485 Data Bus Output Into 4 Managed Branches
- Each Managed Branch Can Have 2 Parallel Home Run Cables (Total Of 8 Home Runs)
- EOL Termination Of Each Branch Insures Proper Operation And Supervision
- Works With Std. 4 Conductor Home Run Wire
- An Additional Unit May Be Connected In Parallel To The Control For Expanding Total Capacity
- Includes Mounting Rails for ELK-SWB Boxes
- Inputs: Elevator Screw Terminals, 4 Position
- Output: Elevator Screw Terminals, 4 Position
- Circuit Board Dimensions: 4.9 in. x 2.75 in.