  • Input for a 26 bit Wiegand Reader, such as ELK-106055
  • Input for a Dallas "One-Wire" iButton Reader, such as ELK-MA110
  • Heavy Duty Form "C" Relay Contacts for Switching Door Strike Power
  • Low Current (50mA) Switched Negative (pull to ground) Output for "Door Held Open" Alarm
  • Low Current (10mA) Switched Negative (pull to ground) Output for "System Ready To Arm" indication
  • Low Current (10mA) Switched Negative (pull to ground) Output for "System Armed" indication
  • Supervised Input for RTE (Request To Exit) Button/Device
  • Supervised Input for Door Status Sensor
  • Installs in place of an M1 Keypad and operates from the RS-485 4-Wire Keypad Data Bus
  • Four selectable Time settings for "Request to Exit" and "Door Held Open"
  • Hardware Watchdog Circuit
Item#:
M1KAM
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
Item#:
T-1 5YDS
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
Item#:
PROTEGE 6.5" CEILING
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

An "active" RS-485 data bus hub designed for jobs where an M1Gold or M1EZ8 Control is retrofitting an older panel that has multiple homerun 4 conductor keypad/data wires. It splits the main 485 data bus into 4 managed 485 branches. Each branch can have 2 parallel home run cables for a total of 8 home runs. The end of each cable is EOL terminated to insure proper operation and supervision.
Includes:

  • ELK-M1DBHR Data Bus Hub
  • ELK-SWG Circuit Board Mounting Glides
  • Instructions
Features:
  • Splits The Controls' RS-485 Data Bus Output Into 4 Managed Branches
  • Each Managed Branch Can Have 2 Parallel Home Run Cables (Total Of 8 Home Runs)
  • EOL Termination Of Each Branch Insures Proper Operation And Supervision
  • Works With Std. 4 Conductor Home Run Wire
  • An Additional Unit May Be Connected In Parallel To The Control For Expanding Total Capacity
  • Includes Mounting Rails for ELK-SWB Boxes
Specifications:
  • Inputs: Elevator Screw Terminals, 4 Position
  • Output: Elevator Screw Terminals, 4 Position
  • Circuit Board Dimensions: 4.9 in. x 2.75 in.