  • 100 addresses available on this analog addressable system
  • Additional system capacity achieved via multi-point SLC modules
  • 99 software zones
  • NFPA 72 Compliant Smoke Sensitivity Test Built-In
  • System Operates as Class A or Class B for SLC, P-Link and NACs
  • 5 Amp Power Supply, Expandable to 310 amps
  • 2 NACS, Regulated, Rated at 3 Amps each, expandable to 188
  • 2 Input/Output (I/O) Circuits for system flexibility rated at 1 Amp each
  • Strobe Synchronization and System Wide Sync for Gentex, AMSECO, Cooper Wheelock and System Sensor strobes
  • Dedicated Alarm, Supervisory and Trouble Relays
  • 4,000 Event History Buffer
  • Optional two line DACT with UD-1000 that can report General,Zone or Point Information
  • Built in IP Communicator
  • Ethernet Port for Programming and Network Connectivity
  • E-Mail System Status, Reports and Event Information

Item#:
3992753
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

The 5496 intelligent power module is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with Silent Knight addressable fire alarm control panels. The output circuits can be programmed as notification appliance circuits or auxiliary power for constant, resettable or door holder power.

Features

  • Power supplys advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems
  • Built-in synchronization for appliances from AMSECO, Gentex, Faraday, System Sensor and Wheelock
  • Four regulated and power-limited notification outputs with support of up to two Class A circuit wiring
  • Each output individually mapped through fire alarm control panel programming
  • Outputs can be programmed as Notification Appliance Circuits or as auxiliary power to be used as constant, resettable or door holder power.
  • 3 amps per output circuit
  • UL listed

Item#:
005496
You must be logged in to order this item. Log in here
Single SPDT relay with LED, double-sided adhesive tape, mounting screw, 12" (30.48 cm) leads and six wire-nuts. Power requirements: 0.015 Amps per position @ 24 VDC, 24 VAC, 115 VAC. Contact rating: 10.0 A @ 115 VAC, 7.0 A @ 28 VDC, 250 µA @ 5 VDC.
Item#:
PAM-1
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

The RTS Series complies with the requirements of NFPA 13 and 72 for a room temperature switch to operate at 40°F to protect a dry pipe valve from freezing. The RTS can also be used for other temperature detection applications.

The normally open detector, RTS-O, will close the contact when the temperature drops below 40°F (4,5°C). The normally closed detector, RTS-C, will open the contact when the temperature drops below 40°F (4,5°C). The detector will automatically reset to the normal state when the temperature rises above 40°F (4,5°C). The RTS Series Room Temperature Sensors are precision engineered, designed and manufactured for commercial or residential use.

Item#: