Features:

  • Available in 13 languages
  • Global partition status
  • Full 32-character programmable labels
  • Modern, slim-line landscape keypad
  • Enlarged keypad buttons
  • 5 programmable function keys
  • Intuitive clock programming*
  • Input/Output terminal can be programmed to operate as a zone input, programmable output or as a low temperature sensor
  • 3 one-touch emergency keys
  • Multiple door chime per zone
  • Adjustable backlight and keypad buzzer
  • Wire channel
  • Dual wall-mount and front cover tamper
  • Easy-to-install mounting hinge
  • Surface or single-gang box mount
  • AC status ICON
  • v1.3 includes easy wireless device enrollment process with v4.6 panel and pre-programmed label libraries (English, French and Spanish)
* Feature only available with new PowerSeries control panels (PC1616, PC1832 and PC1864)

Item#:
PK5500
You must be logged in to order this item. Log in here

Features:

  • PC4116 adds 16 hardwire zones
  • AUX power rated at 250 mA (PTC protected)

Item#:
PC4116
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
Allows a proximity card or fob to be used with the ELK-M1KP and ELK-M1KPB Keypads to quickly arm, disarm, operate a door strike, etc. Ideal for higher security installations and as an alternative to remembering PIN codes. Plugs into back of the Keypad. Uses M1PRC cards or M1PRF fobs. Includes one prox card. 
  • Simple Plug-in Installation 
  • Compatible with Clamshell Style (Credit Card size) Proximity Cards (ELK-M1PRC) 
  • Compatible with Keychain Style Proximity Fobs (ELK-M1PRF) 
  • Low Current Draw 
  • Substitutes for User Code Pin Entry Reader Format: 26 bit Wiegand 
  • 5 Pin Plug-in Connector 
  • Operating Voltage: 5 VDC from Keypad 
  • Current Draw: ~20 mA. 
  • Size: 1.875" W x 1" H x .375" D
Item#:
M1PR
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
The ELK-M1XSP is a "3 in 1" product for additional serial ports and for integration with lighting systems and thermostats. Jumpers on the M1XSP select the appropriate application, connection, and protocol. Best of all, the M1XSP operates from the 4-wire (RS-485) M1 Keypad data bus, allowing RS-232 ports to be located long distances from the control. The M1 Gold and M1EZ8 support up to 7 M1XSPs. The communications baud rate is adjustable from 300 to 38,400 baud. The unit comes complete with cable and a black surface mountable housing. 
  • Adapts the M1 to various Lighting control products which use "serial" communications. I.E.,OnQ-ALC, PCS-UPB, Centralite, etc. 
  • Adapts HVAC Communicating Thermostats from RCS, Aprilaire, and HAI to the M1 Cross Platform Control
  • Expands the RS-232 Serial Ports of the M1 Control 
  • Operates from the M1 Data Bus 
  • DIP Switch Address Settings 
  • Jumper Options and LED Diagnostic indicator 
  • On-Board EOL Bus Termination Jumper 
  • Flash Memory for Firmware Updating
  • Maximum Expandable Ports (Units): 7 
  • Operating Voltage: 12 Volts D.C. 
  • Current Draw: 31mA 
  • Housing Dimensions: 4.375" x 3.0" x 1.125"
  • Circuit Board Dimensions: 3.5" x 2.75"
Item#:
M1XSP
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
The ELK-M1PCSPIM is a special Powerline Interface Module containing a built-in M1XSP Serial Port chip. This all-in-one device makes it easy to permanently connect the ELK M1 Control to a UPB network. Simply locate a convenient unused AC Power Outlet, connect a cable from the M1 data bus to the four (4) terminals on the ELKM1 PCSPIM, and perform an M1 data bus enrollment. The long distance capability of the M1 data bus makes it possible to locate the ELKM1 PCSPIM virtually anywhere, without a lot of complex or ugly cabling or connections. UPB utilizes the AC wiring circuit for transmission, without new or additional wiring, and without radio frequency signals.
  • All-in-one device for interfacing M1 with UPB.
  • Compact interface requires small amount of space
  • Easy hookup - requires only the 4-wire data bus connection. * NO 9-Pin Serial Cable * 
  • Includes UPB Status light (multicolored) AND a M1 Data Bus Status Light (Green) -- enhances the ability to diagnose and troubleshoot
  • Lower cost than purchasing separate and M1XSP and PCSPIM products.
  • Removable 4-pin terminal block connection
  • Power: 
    • -UPB Network circuitry – powered from the AC "Primary" Line.
    • -M1 Data Bus Device circuitry – powered (12VDC) from the M1 Data Bus (+) & (-) terminals. 
    • NOTE: Loss of AC primary power should not result in a missing data bus device trouble.
  • Current Draw from M1: ~30mA @ 12 VDC
  • M1 Bus Device Address: Preset at Address #7 [Requires bus module enrollment]
  • Firmware required: 1.0.42 (std. firmware) or later
Item#:
M1PCSPIM
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
|◀ 145 - 156 of 207 ▶|
View:
(Denotes required field.)