Remote 4-output NAC Extender, for 6.5A ttl, or 2A, max. on any 1 output. Red 14 x 16" can, connects to 120VAC, supports 24V 16Ah standby batts.  Supervised, fire bus connection. System Sensor and Wheelock NAC sync. (5/system, for 20 add’l NAC circuits ttl.). 3 Programmable relay outputs;  2 low voltage; 1 high-voltage 120V rated relay.
Item#:
GEMC-NAC7S
You must be logged in to order this item. Log in here
Quick View

Altronix AL400ULACM converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC Fail-Safe and/or Fail-Secure outputs with a total of 4A @ 12VDC or 3A @ 24VDC continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.

Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
  • Fire Alarm disconnect input options:
  • a) Normally open (NO) or normally closed (NC) dry contact input.
  • b) Polarity reversal input from FACP signaling circuit.
  • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC not evaluated by UL).
  • Short circuit and thermal overload protection.

Item#:
AL400ULACM
You must be logged in to order this item. Log in here
Quick View

  • 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.
  • Sync protocols include Potter/Amseco, Faraday, Gentex®, System Sensor®, and CooperWheelock®.
  • Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit).
  • Compatible with 12VDC or 24VDC fire panels.
  • Output loop supervision steered to input 1 or input 2.
  • Signal circuit trouble memory (helps identify intermittent loop problems).
  • Common trouble input and output for external trouble signals tie-in.
  • Ground fault detection.
  • Unit includes power supply, red enclosure, cam lock, and battery leads.
Item#:
AL602ULADA
You must be logged in to order this item. Log in here
Quick View

  • 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.
  • Sync protocols include Potter/Amseco, Faraday, Gentex®, System Sensor®, and CooperWheelock®.
  • Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit).
  • Compatible with 12VDC or 24VDC fire panels.
  • Output loop supervision steered to input 1 or input 2.
  • Signal circuit trouble memory (helps identify intermittent loop problems).
  • Common trouble input and output.
  • Ground fault detection.
  • Unit includes power supply, red enclosure, cam lock, and battery leads.
Item#:
AL1002ULADA
You must be logged in to order this item. Log in here
Quick View
You must be logged in to order this item. Log in here
Quick View

  • 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.
  • Sync protocols include Potter/Amseco, Faraday, Gentex®, System Sensor®, and CooperWheelock®.
  • Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit).
  • Compatible with 12VDC or 24VDC fire panels.
  • Output loop supervision steered to input 1 or input 2.
  • Signal circuit trouble memory (helps identify intermittent loop problems).
  • Common trouble input and output.
  • Ground fault detection.
  • Unit includes power supply, red enclosure, cam lock, and battery leads.
Item#:
AL1002ULADAJ
You must be logged in to order this item. Log in here
Quick View

  • 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.
  • Sync protocols include Potter/Amseco, Faraday, Gentex®, System Sensor®, and CooperWheelock®.
  • Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit).
  • Compatible with 12VDC or 24VDC fire panels.
  • Output loop supervision steered to input 1 or input 2.
  • Signal circuit trouble memory (helps identify intermittent loop problems).
  • Common trouble input and output.
  • Ground fault detection.
  • Unit includes power supply, red enclosure, cam lock, and battery leads.
Item#:
AL802ULADA
You must be logged in to order this item. Log in here
Quick View

The 5895XL intelligent power module is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with Silent Knight addressable fire alarm control panels. Six Flexput circuits can be programmed as notification appliance circuits, conventional initiation circuit, or auxiliary power for constant, resettable or door holder power. The 5895XL also provides a conditioned SBUS circuit allowing up to an additional 6,000 feet of wiring for SBUS devices.

Features

  • 6A output power
  • Six Flexput circuits rated at 3A each can be programmed as notification appliance circuits, auxiliary power, or initiation circuits
  • Supports Class A configuration for SBUS and Flexput circuits
  • Each output individually mapped through fire alarm control panel programming
  • Two form C programmable relays rated at 2.5A at 24VDC
  • SBUS repeater conditions the RS-485 signal
  • Room in cabinet to mount two 5815XL SLC expanders
  • Built-in synchronization for appliances from AMSECO, Gentex, Faraday, System Sensor, and Wheelock
  • UL listed

Item#:
005895XL
You must be logged in to order this item. Log in here
Quick View

The 5496 intelligent power module is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with Silent Knight addressable fire alarm control panels. The output circuits can be programmed as notification appliance circuits or auxiliary power for constant, resettable or door holder power.

Features

  • Power supplys advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems
  • Built-in synchronization for appliances from AMSECO, Gentex, Faraday, System Sensor and Wheelock
  • Four regulated and power-limited notification outputs with support of up to two Class A circuit wiring
  • Each output individually mapped through fire alarm control panel programming
  • Outputs can be programmed as Notification Appliance Circuits or as auxiliary power to be used as constant, resettable or door holder power.
  • 3 amps per output circuit
  • UL listed

Item#:
005496
You must be logged in to order this item. Log in here
Quick View
Item#:
PE-10SN
You must be logged in to order this item. Log in here
View:
BoxesList
Compare Selected Items