- Voltage: 120VAC, 60Hz, 3.5A max.
- Fusing: 5A / 250V.
Output
- Voltage: Factory set at 24VDC.
- Current: 6A continuous.
- Maximum Supply Current for Main and Aux. Outputs on eFlow6NB Power Supply board and ACMS8 Access Power Controller’s outputs is 5.6A.
- Auxiliary: Class 2 power-limited @ 1A (unswitched).
- Other: Overvoltage protection. Filtered and regulated.
- Built-in charger for sealed lead acid or gel type batteries (if batteries are required, install separate battery enclosure RE2).
- Automatic switch over to stand-by battery when AC fails.
- Zero voltage drop when unit switches over to battery backup (AC failure condition).
- Supervised: Latching or non latching.
- EOL: 10K Resistor.
- AC Failure: Form “C” contacts.
- Battery: Form “C” contacts.
- Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. Prevents deep battery discharge.
- Input: 120VAC is present.
- DC Output: Powered.
- Battery: Discharged or not connected.
Input
- Voltage: 24VDC from eFlow6NB and 12VDC from VR6.
- Fusing: 15A / 32V.
Output
- Voltage: 12 or 24VDC individually selectable.
- Eight (8) selectable 12VDC - 24VDC independently controlled outputs or eight (8) indepently controlled Form “C” relay outputs:
- a) Fail-Safe and/or Fail-Secure power outputs.
- b) Form “C” Relays. 28VAC or VDC @ 2.5A Rated.
- c) Auxiliary power outputs (unswitched).
- d) Any combination of the above.
- Any of the eight (8) fuse protected power outputs are selectable to follow power Input 1 or Input 2.
- Individual outputs may be set to OFF position for servicing.
- Fuses Rating: 2.5A / 32VDC.
Indicators (LED)
- Red LEDs: Outputs are triggered (relays energized).
- Blue LED: FACP disconnect is triggered.
Individual voltage LEDs
- Green: 12VDC
- Red/Green: 24VDC
The NXT-4X4 Input/Output Expansion Module provides functionality to any Doors NetXtreme access control system by adding auxiliary I/O that can be used for additional access control functionality, monitoring non-reader doors or other devices, and creating powerful action sequences by linking input triggers to outputs. The module can be connected anywhere along the RS-485 trunk, most commonly at the controller or near a reader. One module can be added per trunk, allowing up to an extra 8 inputs and 8 outputs on an NXT-2D Controller and an extra 16 inputs and outputs on an NXT-4D controller.
The module's relays are re-assignable and interchangeable with the main controller's relays. The module can be mounted next to the door providing local door control and local door alarm functions while minimizing the cable bundle from door to controller. The unit also has a port to plug in a reader interface module (NXT-RMX) to allow Keri MS reader signals to be sent down the RS-485 line.
Features