|◀ 277 - 288 of 857 ▶|
View:
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

Altronix eFlow104N16 is a power supply/charger that converts a 120VAC 60Hz input into sixteen fuse protected 24VDC outputs with a total of 10A max. The unit includes an unswitched aux. output. It also offers a suite of features that includes fire alarm disconnect, over voltage protection, and low power disconnect which prevents deep discharge of stand-by batteries.

Features

  • Short circuit and overload protection.
  • Unit is complete with power supply, enclosure, battery leads and cam lock.

Item#:
EFLOW104N16
You must be logged in to order this item. Log in here
Item#:
MAXFIT55P32D
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
Item#:
EFLOW104NA8DQM
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
Item#:
MAXFIT77F
You must be logged in to order this item. Log in here

Altronix ACM4 converts one (1) 12 to 24 VAC or VDC input into four (4) independently controlled fuse protected outputs. These power outputs can be converted to dry form C contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACM4 will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. Units are designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the four (4) outputs.

Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the four (4) outputs.
    Fire Alarm disconnect input options:
    • a) Normally open (NO) or normally closed (NC) dry contact input.
    • b) Polarity reversal input from FACP signaling circuit.
  • FACP output relay (form "C" contact rated @ 1A 28VDC not evaluated by UL).
  • Removable terminal blocks facilitate ease of installation.

Item#:
ACM4
You must be logged in to order this item. Log in here
|◀ 277 - 288 of 857 ▶|
View:
(Denotes required field.)