Input

  • Input 115VAC, 60Hz, 3A.
  • Input fuse rated @ 3.5A/250V.
Output
  • 12VDC or 24VDC selectable output.
  • 12VDC @ 4A or 24VDC @ 3A supply current.
  • Class 2 Rated power limited output.
  • Filtered and electronically regulated output.
  • Short circuit and thermal overload protection.
Battery Backup
  • Built-in charger for sealed lead acid or gel type batteries.
  • Automatic switch over to stand-by battery when AC fails.
Supervision
  • AC fail supervision (form "C" contacts).
  • Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
  • Low battery supervision (form "C" contacts).
  • Battery presence supervision (form "C" contacts).
Visual Indicators
  • AC input, DC outputand Battery LED indicators.
Item#:
AL400ULX
You must be logged in to order this item. Log in here
  • 720p Live Video
  • Doorbell with integrated camera
  • PIR-triggered motion sensitivity (low, med, high settings)
  • Digital Microphone and Speaker
  • Doorbell-triggered clips
  • Motion-triggered automation rules
  • Real-Time Alerts
  • Battery heater for improved cold weather performance 
Item#:
ADC-VDB106X
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

Compatible with DSC LTE Alarm Communicators (Universal - LE4000/LE4010/LE4010CF and PowerSeries Neo  LE2080(R) / TL280LE(R))

Item#:
LTE-50ANT
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

Altronix AL400ULXB2 UL Listed Sub-Assembly power supply/charger converts a 115VAC, 60Hz input into a single 12VDC or 24VDC Class 2 Rated power-limited output. It also offers a suite of features that includes AC fail supervision, battery presence, and low battery supervision.
This product replace AL4000ULXB

Specifications:
Input:

  • Input 115VAC, 60Hz, 3A.
  • Input fuse rated @ 3.5A/250V.
Output:
  • 12VDC or 24VDC selectable output.
  • 12VDC @ 4A or 24VDC @ 3A supply current.
  • Class 2 Rated power limited output.
  • Filtered and electronically regulated output.
  • Short circuit and thermal overload protection.
Battery Backup:
  • Built-in charger for sealed lead acid or gel type batteries.
  • Automatic switch over to stand-by battery when AC fails.
Supervision:
  • AC fail supervision (form C contacts).
  • Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
  • Low battery supervision (form C contacts).
  • Battery presence supervision (form C contacts).
Visual Indicators:
  • AC input, DC outputand Battery LED indicators.
Electrical:
  • Temperature:
    • Operating: 0° C to 49° C (32° F to 120° F).
    • Storage: - 20° C to 70° C ( - 4° F to 158° F).
  • Relative Humidity 85% +/- 5%.
    • BTU/Hr (approx.):
      • 12VDC: 25 BTU/Hr.
      • 24VDC: 37 BTU/Hr.
  • System AC input VA requirement: 402.5VA.