  • Sounds selectable tones or voice messages
  • Monitor 4 devices at 1 location
  • Offers 10 tones/tunes, 53 words (English or Spanish)
  • Up to 1000 feet (line of sight), 433 MHz
  • Supervised for low battery and connection
  • Easy programming voice prompt
  • Can be mounted on a wall or set on a table
  • Can be used with all STI Wireless Alerts
  • CE, FCC and IC Compliant

Item#:
STI-V34104
You must be logged in to order this item. Log in here

The 2GIG 319/345 MHz Receiver is designed to be installed into the 2GIG GC2 Panel. This Receiver is a dual frequency device, enabling communication between the Control Panel and peripheral devices that use either the 319 or the 345 MHz frequency.

Features:

  • InterLogix-compatible 319MHz wireless protocol
  • Integrated into panel, no external power supply or translator hardware
  • Easy to install into any GC2 panel
  • Accepts up to 48 wireless devices using 2GIG, Honeywell, or InterLogix protocols
  • External antenna provides reliable range performance
Item#:
2GIG-DREC2-319
You must be logged in to order this item. Log in here

The TR5164-433 wireless receiver transforms any PowerSeries control panel into a wireless alarm system capable of supporting up to 4 wirefree keypads, 60 wireless zones and 16 wireless keys (wireless keys do not use up zone slots).
The TR5164-433 is compatible with all PowerSeries PC 1616, 1832, 1864 control panels v4.6+

Features:

  • Supports both 2-way and 1-way wireless devices
  • Supports 4 wire-free keypads WT5500
  • Supports 16 Wireless Keys (any combination of 1-way or 2-way wireless keys)
  • Supports 60 wireless zones on PC1864
  • 8-partition support for 1-way wireless keys
  • Compatible with PC1616, PC1832 and PC1864 v4.6+

Item#:
TR5164-433
You must be logged in to order this item. Log in here
This zone input device is an addressable two-zone input expander for Honeywell V-Plex® addressable systems. It is ideal for systems where additional zone inputs are required. The device provides a supervised and unsupervised zone that is compatible with any conventional detection device providing a dry contact output. Examples of these devices are door and window contacts, motion, glass, smoke and heat detectors, Fire Pull Stations and help-request buttons. It can also be used to monitor machine status outputs for normal, trouble and alarm status, environmental conditions and in other critical status applications.
  • Can be located anywhere along the two-wire addressable V-Plex® bus
  • Converts any conventional detection device to an addressable device. Conventional detector must provide dry-contact output.
  • System automatically learns device serial number so no DIP switch addressing is required
  • Small size fits easily into most sensing detector enclosures or splice boxes
  • Two zone inputs: one supervised with 10K EOL resistor, one unsupervised loop
  • Loop 1 provides a broad, 300 ohm tolerance
  • Supervised for open, shorted or normal circuit conditions
  • UL Listed for commercial burglary and fire alarm applications
Item#:
4193SNP
You must be logged in to order this item. Log in here
Honeywell's 4232CBM Connected Building Module is designed to support VISTA security panels with a variety of Honeywell and third-party hardware and software products. This module is intended for applications such as home or building automation. It enables communication between products by providing high-speed RS232 and RS422 serial interfaces for connection to external systems and a standard four-wire ECP interface for connection to the security control panel. 
  • Mounts directly in control panel cabinet using double-sided tape (included)
  • Three-wire RS232 or four-wire RS422 interface to external equipment
  • Four status LEDs for system troubleshooting
  • Driver software is required to use this module; this software is provided separately. To obtain drivers, consult the third party vendor with whom you need to work.
Item#:
4232CBM
You must be logged in to order this item. Log in here
The 4208U Remote Point Module (RPM) is an eight-zone expander that allows the use of available expansion zones on ADEMCO controls that support V-Plex polling loop devices.
  • Can be optionally powered from an external DC power supply to reduce the amount of current draw from the polling loop
  • Uniquely identifies eight EOLR supervised zones (all zones use 10K resistors, supplied)
  • DIP Switches can be used to set zone numbers or serial numbers
  • When used in the serial number mode, each serial number in the selected group can be assigned to any zone number
  • Loops A & B can be programmed for fast (10msec) response
  • Provides cover tamper protection, which may be enabled or disabled via on-board DIP Switches
Item#:
4208U
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
The ADEMCO 4101SN V-PlexTM Single Output Relay Module is an accessory for use with ADEMCO control panels that support serial number addressable polling loop output devices.
  • Form C relay contacts rated at 2A, 28VACNDC with contact supervision.
  • The position of the relay is supervised, but not the actual external contact wiring.
  • Note: Some panels may not support this feature. 
  • One class B/style B EOLR-supervised aux input zone. 
  • Operating power and communication with control panels via the addressable V-PlexTM polling loop. 
  • Electronics mounted in a small plastic case with tamper-protected cover. Suitable for residential and commercial burglary and fire installations.
Item#:
4101SN
You must be logged in to order this item. Log in here
The ADEMCO 4190SN addressable V-PlexTM module is a two-zone expander which allows use of the available expansion zones provided by ADEMCO controls that support V-Plex devices.
Serial mode programmable
  • Left Zone - EOLR supervised, open or closed circuit sensors
  • Right Zone - unsupervised, closed circuit sensors
  • UL listed for fire and burglary installations
The 4190SN consists of two detection loops, known as the left (primary) and right (secondary) loops. The left loop can be used for:
  • Closed-circuit devices with or without EOLR supervision
  • Open-circuit devices, with EOLR supervision
  • Fast-response (10 millisecond) devices
Follow the chart below for cutting the correct jumpers and choosing the correct resistor when using the left loop. The right loop can be used for:
  • Closed-circuit devices only
  • Has no EOLR supervision
  • 400 millisecond response time  
  • The jumpers do not affect the operation of the right loop. The right loop cannot be used alone.
Supervision:
The tamper/supervision response of the 4190SN is determined by the zone response type assigned to the left loop zone. While the system is armed, tamper/supervisory faults will report as alarms if the left loop zone is assigned a burglary response type and will report as troubles if the left loop zone is assigned a non-burglary response type (i.e., fire, panic, aux). While the system is disarmed, tamper/supervisory will always report as troubles.
Item#:
4190SN
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
Item#:
STI-34108
You must be logged in to order this item. Log in here
|◀ 73 - 83 of 83 ▶|
View:
(Denotes required field.)