View:

The ANN-LED annunciator module provides LED annunciation of general system faults and input zones/points when used with a compatible Fire Alarm Control Panel (FACP). The ANNLED module provides alarm (red), trouble (yellow) and supervisory (yellow) indication for up to ten input zones or addressable points. ANN-RLED has red LEDs only for alarm communication of up to 30 addressable points.

The ANN-LED is supplied standard with certain Canadian FACPs as required by ULC.

The ANN-LED and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. An additional two wires are used for 24-volt DC power. A single four-conductor unshielded cable may be used for both power and data communications.

Up to eight ANN-BUS devices may be connected to the ANNBUS of each FACP.

Features

  • ANN-LED connects to the ANN-BUS terminal on the FACP and requires minimal programming.
  • Includes three LEDs for each zone: Alarm, Trouble and Supervisory.
  • Compatible with the MS-9050UD, MS-5UD-3, MS-10UD-7, MRP-2001, MRP-2002, MS9200UDLS version 4.0 or greater, MS-9600LS and MS-9600UDLS.
  • Can be remotely located up to 6,000 feet (1,829 m) from the panel.
  • May be powered by 24 VDC from the host FACP or byremote power supply (requires 24 VDC)

Item#:
ANN-LED
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80 is red; for white, order ANN-80-W.
The ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes control switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.)
Up to eight ANN-80s may be connected to the ANN-BUS of each FACP. No programming is required, which saves time during system commissioning.

Features

  • Listed to UL Standard 864, 9th Edition.
  • Backlit 80-character LCD display (20 characters x 4 lines).
  • Mimics all display information from the host panel.
  • Control switches for System Acknowledge, Signal Silence, Drill, and Reset.
  • Control switches can be independently enabled or disabled at the FACP.
  • Keyswitch enables/disables control switches and mechanically locks annunciator enclosure
  • Keyswitch can be enabled or disabled at the FACP.
  • Enclosure supervised for tamper.
  • System status LEDs for AC Power, Alarm, Trouble, Supervisory, and Alarm Silence.
  • Local sounder can be enabled or disabled at the FACP.
  • ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming.
  • Displays device type identifiers, individual point alarm, trouble, supervisory, zone, and custom alpha labels.
  • Time-and date display field.
  • Surface mount directly to wall or to single, double, or 4in. square electrical box.
  • Semi-flush mount to single, double, or 4" square electrical box. Use ANN-SB80KIT for angled view mounting.
  • Can be remotely located up to 6,000 feet (1,800 m) from the panel.
  • Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs.
  • May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC).
  • Up to eight ANN-80s can be connected on the ANN-BUS

Item#:
ANN-80
You must be logged in to order this item. Log in here

The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80 is red; for white, order ANN-80-W.
The ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes control switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.)
Up to eight ANN-80s may be connected to the ANN-BUS of each FACP. No programming is required, which saves time during system commissioning.

Features

  • Listed to UL Standard 864, 9th Edition.
  • Backlit 80-character LCD display (20 characters x 4 lines).
  • Mimics all display information from the host panel.
  • Control switches for System Acknowledge, Signal Silence, Drill, and Reset.
  • Control switches can be independently enabled or disabled at the FACP.
  • Keyswitch enables/disables control switches and mechanically locks annunciator enclosure
  • Keyswitch can be enabled or disabled at the FACP.
  • Enclosure supervised for tamper.
  • System status LEDs for AC Power, Alarm, Trouble, Supervisory, and Alarm Silence.
  • Local sounder can be enabled or disabled at the FACP.
  • ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming.
  • Displays device type identifiers, individual point alarm, trouble, supervisory, zone, and custom alpha labels.
  • Time-and date display field.
  • Surface mount directly to wall or to single, double, or 4in. square electrical box.
  • Semi-flush mount to single, double, or 4" square electrical box. Use ANN-SB80KIT for angled view mounting.
  • Can be remotely located up to 6,000 feet (1,800 m) from the panel.
  • Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs.
  • May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC).
  • Up to eight ANN-80s can be connected on the ANN-BUS

Item#:
ANN-80-W
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

The 5860 and 5860R are 4 x 20 LCD remote annunciators used with Silent Knight addressable fire alarm control panels. The 5860R is red and the 5860 is gray to match virtually any decor.

Features

  • 80-character backlit LCD display (4 lines with 20 characters on each line)
  • Tactile and audible feedback
  • Accepts user codes or fire fighters key
  • Install up to eight annunciators per fire alarm control panel
  • Available in red or light gray
  • UL listed

Item#:
005860
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

The 5860 and 5860R are 4 x 20 LCD remote annunciators used with Silent Knight addressable fire alarm control panels. The 5860R is red and the 5860 is gray to match virtually any decor.

Features

  • 80-character backlit LCD display (4 lines with 20 characters on each line)
  • Tactile and audible feedback
  • Accepts user codes or fire fighters key
  • Install up to eight annunciators per fire alarm control panel
  • Available in red or light gray
  • UL listed

Item#:
005860R
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
The ANN-100 annunciator is a backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-100 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-100 is red.
  • Approved for use in Canada
  • Control switches for System Acknowledge, Signal Silence, Drill, and Reset
  • Control switches can be independently enabled or disabled at the FACP
  • Keyswitch enables/disables control switches and mechanically locks annunciator enclosure
  • Enclosure supervised for tamper
  • Local sounder can be enabled or disabled at the FACP
  • Displays device type identifiers, individual point alarm, trouble, supervisory, zone, and custom alpha labels
  • Surface mount directly to wall
  • Can be remotely located up to 6,000 feet (1,800 m) from the panel
  • Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs
Item#:
ANN-100
You must be logged in to order this item. Log in here

The RA100Z and RA100ZA remote annunciators are designed for both conventional and intelligent applications. Their red LED provides visual indication of an alarm condition.

Item#:
RA100Z
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
View:
(Denotes required field.)