Converts the ECC-50/100 primary amplifier to a 70V

Item#:
ECC-XRM-70V
You must be logged in to order this item. Log in here

The ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels that may be used for fire applications, mass notification applications or both. These state-of the-art Primary Operator Consoles (POCs) are capable of producing either 50 or 100 watts of audio power that can be distributed to up to eight speaker circuits (i.e., zones).

Features

  • UL Listed to UL2572 Communication (Control Units Mass Notification Systems).
  • Modular design for maximum system flexibility and easy expansion.
  • 50 watts of 25 V audio power (expandable to 100 watts) RMS.
  • Optional amplifier can be configured as a backup in the event the primary amplifier fails. Amplifiers are independently powered to eliminate system interruption during a short circuit condition
  • Eight Command Input Circuits to activate messages 1 to 8:
  • Seamless integration and control when connected to select Fire-Lite panels through the ANN/ACS (EIA-485) communication bus.
  • Speaker circuits are expandable by up to 8 outputs (With an optional circuit expander module).
  • Removable terminal blocks for ease of servicing and module replacement.
  • 2 amp Notification Appliance Circuit (NAC) output, sync generator, or follower for System Sensor, Wheelock or Gentex protocols:
  • Integral supervised microphone.
  • 520HZ square wave tones can be uploaded to ECC-50/100 to meet NFPA Low Frequency requirements
Item#:
ECC-50/100
You must be logged in to order this item. Log in here

  • 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.
  • Sync protocols include Potter/Amseco, Faraday, Gentex®, System Sensor®, and CooperWheelock®.
  • Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit).
  • Compatible with 12VDC or 24VDC fire panels.
  • Output loop supervision steered to input 1 or input 2.
  • Signal circuit trouble memory (helps identify intermittent loop problems).
  • Common trouble input and output.
  • Ground fault detection.
  • Unit includes power supply, red enclosure, cam lock, and battery leads.
Item#:
AL1002ULADAJ
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

  • 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.
  • Sync protocols include Potter/Amseco, Faraday, Gentex®, System Sensor®, and CooperWheelock®.
  • Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit).
  • Compatible with 12VDC or 24VDC fire panels.
  • Output loop supervision steered to input 1 or input 2.
  • Signal circuit trouble memory (helps identify intermittent loop problems).
  • Common trouble input and output.
  • Ground fault detection.
  • Unit includes power supply, red enclosure, cam lock, and battery leads.
Item#:
AL802ULADA
You must be logged in to order this item. Log in here

Supervises up to 5 remote microphones

Item#:
EVX-SC
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

  • Circuit breaker lockout tab
  • Hex key
  • Panel identification stickers
Item#:
ELOCK-FA
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

  • Amplifier Configurations:
    • 50 watts with 50 watts as backup.
    • 100 watt single channel.
    • 100 watt single channel with 50 watts backup using EVS-100WBU.