Altronix ACM8CB converts one (1) 12 to 24 volt AC or DC input into eight (8) independently controlled Class 2 rated PTC protected power-limited auto-resettable outputs rated at 2.5A each. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACM8CB will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.

Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
    Fire Alarm disconnect input options:
    • a) Normally open (NO) or normally closed (NC) dry contact input.
    • b) Polarity reversal input from FACP signaling circuit.
  • FACP output relay (form "C" contact rated @ 1A 28VDC not evaluated by UL).
  • Removable terminal blocks facilitate ease of installation.

Item#:
ACM8CB
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

Features

  • Since customers sometimes are already using existing non-ZK card readers and cards, ZK also provides 125 KHz key fobs which can be clipped on to cards having a badge clip slot
  • For customers having non-ZK cards with no badge clip slot, we also offer 125 KHz self-adhesive RFID discs which can be easily adhered

Item#:
PROX-KEY-FOB
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
Altronix StrikeIt4 will operate up to two (2) low current lock hardware devices simultaneously. It is designed to operate motorized electric latch retraction exit devices, electric strikes, mag-locks, electric mortise and cylindrical locksets, etc. Each lock output has an adjustable re-lock delay timer. It will control a pair of doors simultaneously, or independently control two single door leafs. StrikeIt4 has integrated output relays which trigger automatic door operators and control ADA activation push plates/accessories. In addition, one (1) 12VDC and one (1) 24VDC unswitched auxiliary voltage outputs are provided for powering ancillary devices. A configurable FACP interface will either remove or apply power from the lock outputs when activated. LED status indicators are provided to monitor input status, battery condition, AC power loss, and FACP status. Intelligent logic provides protection against accidental shorting of lock outputs.
Input
  • Input 115VAC, 60Hz, 2.5A or 230VAC, 50Hz, 1.5A.
  • Two (2) Normally Open (N.O.) trigger inputs (Input 1 and Input 2).
  • FACP Normally Closed (N.C.) input.
  • Two normally open ADA inputs for special mode of interfacing with automatic door operators.
Outputs
  • Two (2) 19.8VDC-26.4VDC rated individually controlled lock outputs configurable for fail-secure or fail-safe electronic locking hardware for applications with battery back-up. 24VDC-26.4VDC rated for applications without battery back-up (US applications only). Current rating 2A combined.
  • One (1) 19.8VDC-26.4VDC @ 0.8A rated filtered regulated auxiliary output for applications with battery back-up, 24VDC-26.4VDC @ 0.8A rated for applications in US not requiring battery back-up. Not affected by FACP trigger.
  • One (1) 12VDC filtered regulated auxiliary output rated 0.5A. Not affected by FACP trigger.
  • Two (2) follower Normally Open relay outputs for controlling ADA actuators/accessories rated 28VDC @ 0.5A.
  • Two momentary door operator activation relay outputs.
  • Trouble relay output indicating low AC voltage trouble and battery trouble.
Battery Backup
  • Battery leads included.
  • When 7AH batteries are used, battery capacity for emergency stand-by is 30 minutes.
  • Built-in charger for sealed lead acid batteries.
  • Maximum charge current 650mA.
  • Automatic switch over to stand-by battery when AC fails.
Visual Indicators
  • Green AC Power LED indicates AC presence.
  • Red trigger output LEDs indicate panic device status / opened (activated, short circuit).
  • Green Fire Alarm Interface (FAI) LED indicates FACP interface is activated.
  • Red Battery LED indicates low battery during AC failure and battery test.
  • Green AC status LED indicates loss of AC power.
Fire Alarm Disconnect
  • Normally Closed FACP trigger input.
Programmable Fire Alarm Disconnect options:
  • Removes power to outputs and disables delayed follower relays.
  • Connects power to lock outputs and enables delayed follower relays.
Item#:
STRIKEIT4
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
|◀ 265 - 276 of 22390 ▶|
View:
(Denotes required field.)