|◀ 25 - 36 of 179 ▶|
View:

  • 100 addresses available on this analog addressable system
  • Additional system capacity achieved via multi-point SLC modules
  • 99 software zones
  • NFPA 72 Compliant Smoke Sensitivity Test Built-In
  • System Operates as Class A or Class B for SLC, P-Link and NACs
  • 5 Amp Power Supply, Expandable to 310 amps
  • 2 NACS, Regulated, Rated at 3 Amps each, expandable to 188
  • 2 Input/Output (I/O) Circuits for system flexibility rated at 1 Amp each
  • Strobe Synchronization and System Wide Sync for Gentex, AMSECO, Cooper Wheelock and System Sensor strobes
  • Dedicated Alarm, Supervisory and Trouble Relays
  • 4,000 Event History Buffer
  • Optional two line DACT with UD-1000 that can report General,Zone or Point Information
  • Built in IP Communicator
  • Ethernet Port for Programming and Network Connectivity
  • E-Mail System Status, Reports and Event Information

Item#:
3992753
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

  • Integrated Sounder in base
  • 75 dB (UL 464 Listed) sounder output
  • Sounder independent of sensor, allows for a single station, grouped or all-call
  • May be mapped to any device connected to the control panel
  • Terminals accept 22 to 12 AWG wire sizes
  • Supports Class A, Class X and Class B wiring
  • Does not require SLC Loop address
  • UUKL Listed for Smoke Control

Item#:
3992729
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

  • One form C relay as part of the base assembly
  • Relay rating: 2A @ 30VDC, 0.5A @ 125VAC
  • Works independent of the sensors attached
  • May be mapped to any device connected to the Control Panel
  • LED to indicate that the unit is active
  • Separation included in the base for high and low voltage and power limited/non-power limited connections
  • Terminals accept 22 to 12 AWG wire sizes
  • Supports Class A, Class X and Class B wiring
  • Does not require SLC Loop address
  • Product includes a 5 year warranty
  • UUKL Listed for Smoke Control

Item#:
3992728
You must be logged in to order this item. Log in here

  • Single addressable red LED indicator
  • Mounts in a standard 4 or double gang box
  • SLC Class A, Class X & Class B
  • Wiring terminals accessible when mounted in box
  • All wiring terminals accept 22 to 12 AWG
  • Product includes a 5 year warranty
  • UUKL Listed for Smoke Control