Home  >  Fire  >  Controls/Panels/Kits  > 10 Zone Conventional Fire Control Panel with 7 AMP Power Supply

10 Zone Conventional Fire Control Panel with 7 AMP Power Supply

Item #:MS-10UD-7 
You must be logged in to order this item.
Log in here
MS-10UD-7

MS-10UD-7 is a ten zone conventional fire control panel has features normally found in more expensive addressable systems. The MS-10UD-7 is fully programmable via built-in keypad and 80 character LCD display, so you do not need an external programmer. The ten zones panel has a built-in Digital Alarm Communicator Transmitter (DACT) and availability to add optional equipment: Remote annunciator, Relay module, LED Driver module, Transmitter module and Printer interface module.

Features

  • Ten-zone Style B (Class B) or Five-zone Style D (Class A) with optional module
  • Four NAC Circuits Style Y (Class B) or Four NAC Circuits Style Z (Class A) with optional modules
  • Built-in NAC synchronization for System Sensor, Wheelock, Gentex, Faraday and Amseco devices
  • Built in programmer: Integral 80 character LCD display with backlighting and keypad
  • Annunciator bus supports up to 8 devices, including ANN-80 LCD Remote Annunciator, ANN-S/PG remote serial or parallel printer gateway, ANN-RLY, 10 form C relay board, ANN-LED Zone annunciator and ANN-I/O LED driver board for graphic annunciators
  • Built-in two-line digital communicator for off premises monitoring
  • Three Form-C programmable relays
  • 7.0 amps total usable current

Fire Control/Panels/Kits

Type
Conventional
Brand
FireLite
Item #:
ANN-I/O

10 Input Zones Annunciator Module

Features

  • ANN-LED connects to the ANN-BUS terminal on the FACP and requires minimal programming.
  • Includes three LEDs for each zone: Alarm, Trouble and Supervisory.
  • Compatible with the MS-9050UD, MS-5UD-3, MS-10UD-7, MRP-2001, MRP-2002, MS9200UDLS version 4.0 or greater, MS-9600LS and MS-9600UDLS.
  • Can be remotely located up to 6,000 feet (1,829 m) from the panel.
  • May be powered by 24 VDC from the host FACP or byremote power supply (requires 24 VDC)

Item #:
ANN-LED

10 RELAY BOARD, MOUNTS IN COMM ON ENCLOSURE MS-5UD-3, MS-10UD

  • ANN-RLY connects to the ANN-BUS terminal on the FACP and requires minimal programming.
  • Provides 10 programmable Form-C relays.
  • Ten Form-C relays can be programmed for various functions; Alarm, Trouble, Supervisory, AC Loss, Waterflow Delay,
  • Input Zones and Silenceable Alarm.
  • Compatible with the MS9600LS, MS-9600UDLS, MS-9200UDLS, MS-9050UD, MS-5UD-3, MRP-2001, MRP-2002and MS-10UD-7.
  • May be powered by 24 VDC from the host FACP or by remote power supply
  • Up to eight ANN-BUS devices may be connected to the ANN-BUS of each FACP.
Item #: